A personal blender can leak when its cup is overfilled, its blade is loose, a cup or blade seal is damaged, or pressure builds inside the sealed cup. Check the fill level and fit, then follow the cause-by-cause checks for your model.
Before removing parts, stop the appliance, disconnect its power supply and wait for all movement to stop; let hot parts and contents cool before handling them.
Is liquid getting into, or coming from inside, the base?
If liquid has entered the motor base or electrical housing, or dark or oily-looking liquid is coming from inside it, stop using it, unplug it only if it is safe to do so, and take your claim, with your receipt, to the place of purchase (the manufacturer warranty is 12 months from the date of purchase). Keep a rechargeable appliance disconnected from its charger; do not open the housing or run another cycle to test it.
If a leak continues after the checks, or the source is unclear, leave the appliance off and use the same help link. Include the full model name and where the liquid appeared.
If a step above directs you to our team, or you need help with an unresolved issue in this article, see our warranty article.
NutriBullet Ultra 1200
The NutriBullet Ultra 1200 can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Ultra 1200 cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Ultra 1200 cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Ultra 1200 Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Ultra 1200 cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Ultra 1200 cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Ultra 1200 cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Ultra 1200 mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. After repeated cycles, allow the contents to settle for at least 10โ15 minutes; a warm cup requires the longer cooling procedure above.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Ultra 1200 cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Ultra 1200. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Ultra 1200, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Ultra 1200 Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 900 Series
The NutriBullet 900 Series can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 900 Series cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 900 Series cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 900 Series extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 900 Series cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 900 Series cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 900 Series cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 900 Series mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 900 Series cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 900 Series, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 900 Series Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 900 Essentials Set (AU and NZ)
The NutriBullet 900 Essentials Set NB9-0807DG (AU and NZ) can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Unplug the motor base and wait until every moving part has stopped before handling or cleaning it.
Is the cup overfilled or the extractor blade loose?
- For extractor-blade blending, add ingredients and liquid without going above the cupโs MAX line.
- Twist the extractor blade onto the cup until tightly sealed.
Are any cup tabs damaged?
- Check all three tabs on the cup. Stop using the cup and replace it if a tab is broken, damaged or missing.
Is the extractor blade worn or damaged?
- With the NutriBullet 900 Essentials Set NB9-0807DG unplugged and all movement stopped, inspect the detached extractor blade before refitting it.
- Stop using a worn or damaged blade and replace the complete extractor blade assembly before further use.
Is the blade gasket loose or damaged?
- Check that the gasket is intact and completely seated in the extractor blade without pulling it out.
- Do not remove the gasket. If it is loose, dislodged or damaged, stop using that blade and replace the complete blade assembly.
Were hot or carbonated ingredients used?
- Hot ingredients and gas from carbonated liquids can build pressure inside the sealed NutriBullet 900 Essentials Set NB9-0807DG cup. Do not blend them.
- Stop blending and leave a warm cup to cool before carefully opening it pointed away from your body. Use only cool or room-temperature ingredients for the next batch.
Has blending heated the cup, or was a mixture left sealed inside?
- Do not blend continuously for more than one minute. Blade friction can heat the contents and build pressure; let a warm vessel cool before carefully opening it away from your body.
- Do not leave blended mixtures sealed for long periods. They can ferment and build pressure. Release pressure carefully once the cup has cooled before storing the mixture.
How do I clean sticky spills on the base?
- Wipe the accessible motor base with a cloth dampened with warm soapy water. NEVER submerge the motor base in water.
- Use a small brush if needed to clean sticky debris around the white actuator tabs inside the unplugged base.
What if the blender is damaged or malfunctions? Stop using it.
NutriBullet 900 Mega Pack (AU and NZ)
The NutriBullet 900 Mega Pack NB9-1107AK (AU and NZ) can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Unplug the motor base and wait until every moving part has stopped before handling or cleaning it.
Is the cup overfilled or the extractor blade loose?
- For extractor-blade blending, add ingredients and liquid without going above the cupโs MAX line.
- Twist the extractor blade onto the cup until tightly sealed.
Are any cup tabs damaged?
- Check all three tabs on the cup. Stop using the cup and replace it if a tab is broken, damaged or missing.
Is the extractor blade worn or damaged?
- With the NutriBullet 900 Mega Pack NB9-1107AK unplugged and all movement stopped, inspect the detached extractor blade before refitting it.
- Stop using a worn or damaged blade and replace the complete extractor blade assembly before further use.
Is the blade gasket loose or damaged?
- Check that the gasket is intact and completely seated in the extractor blade without pulling it out.
- Do not remove the gasket. If it is loose, dislodged or damaged, stop using that blade and replace the complete blade assembly.
Were hot or carbonated ingredients used?
- Hot ingredients and gas from carbonated liquids can build pressure inside the sealed NutriBullet 900 Mega Pack NB9-1107AK cup. Do not blend them.
- Stop blending and leave a warm cup to cool before carefully opening it pointed away from your body. Use only cool or room-temperature ingredients for the next batch.
Has blending heated the cup, or was a mixture left sealed inside?
- Do not blend continuously for more than one minute. Blade friction can heat the contents and build pressure; let a warm vessel cool before carefully opening it away from your body.
- Do not leave blended mixtures sealed for long periods. They can ferment and build pressure. Release pressure carefully once the cup has cooled before storing the mixture.
How do I clean sticky spills on the base?
- Wipe the accessible motor base with a cloth dampened with warm soapy water. NEVER submerge the motor base in water.
- Use a small brush if needed to clean sticky debris around the white actuator tabs inside the unplugged base.
What if the blender is damaged or malfunctions? Stop using it.
NutriBullet 600 Series
The NutriBullet 600 Series can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 600 Series cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 600 Series cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 600 Series extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 600 Series cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 600 Series cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 600 Series cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 600 Series mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 600 Series cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 600 Series, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 600 Series Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Ultra 1000 / Ultra 1000 Premium
The NutriBullet Ultra 1000 / Ultra 1000 Premium can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Ultra 1000 / Ultra 1000 Premium cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Ultra 1000 / Ultra 1000 Premium cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Ultra 1000 / Ultra 1000 Premium Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Ultra 1000 / Ultra 1000 Premium cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Ultra 1000 / Ultra 1000 Premium cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Ultra 1000 / Ultra 1000 Premium cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Ultra 1000 / Ultra 1000 Premium mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. After repeated cycles, allow the contents to settle for at least 10โ15 minutes; a warm cup requires the longer cooling procedure above.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Ultra 1000 / Ultra 1000 Premium cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Ultra 1000 / Ultra 1000 Premium. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Ultra 1000 / Ultra 1000 Premium, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Ultra 1000 / Ultra 1000 Premium Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Select 1200 / 2.0 Select 1200
The NutriBullet Select 1200 / 2.0 Select 1200 can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Select 1200 / 2.0 Select 1200 cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and easy-twist extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the easy-twist extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Select 1200 / 2.0 Select 1200 cup and easy-twist extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the easy-twist extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Select 1200 / 2.0 Select 1200 easy-twist extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the easy-twist extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet Select 1200 / 2.0 Select 1200 cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached easy-twist extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Select 1200 / 2.0 Select 1200 cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the easy-twist extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Select 1200 / 2.0 Select 1200 cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Select 1200 / 2.0 Select 1200 mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Are liquid and solid ingredients below the correct pitcher MAX marks?
- Check the NutriBullet Select 1200 / 2.0 Select 1200 pitcher markings before running the blender. Keep liquids below the liquid MAX line and solids below the solid MAX line where separate marks are provided.
- Switch off, disconnect power and wait for the blades to stop, then remove the pitcher and reduce an excessive batch.
- Refit the closed lid before blending again. The ingredients must stay within the appropriate MAX mark after everything has been added.
Are the pitcher lid and its opening securely closed?
- A lid or opening left unsecured can let the NutriBullet Select 1200 / 2.0 Select 1200 pitcher splash from the top. Stop the blades before adjusting the lid.
- Remove the lid and wash food deposits from the lid and pitcher contact surfaces with soap and water, then rinse.
- Place the Pitcher Lid with its Vented Lid Cap attached onto the pitcher, aligned with the handle. The lid must stay fully seated; replace a damaged detachable lid before further use.
Is the pitcher cracked, cloudy or damaged?
- Inspect the clean NutriBullet Select 1200 / 2.0 Select 1200 pitcher, its base and fitting area for cracks, crazing, cloudiness or breakage.
- Replace a damaged pitcher or detachable lid before using it again; do not keep blending to see whether a crack leaks more.
- If liquid continues to escape from the bottom of a sound, correctly fitted pitcher, keep the NutriBullet Select 1200 / 2.0 Select 1200 off and use the help route for the fault.
Did a hot blend splash because it started too fast?
- For a hot blend in the NutriBullet Select 1200 / 2.0 Select 1200 pitcher, the fitted vented lid and the correct fill level help control splashes. Hot ingredients must never be moved to a sealed blending cup.
- Start the pitcher blend on LOW and increase speed only after ingredients are mixed and the surface is steady.
- If the mixture splashes, stop the motor and let it settle before checking the lid and amount. Open the lid cautiously because steam can escape.
Is the easy-twist extractor blade tight on the pitcher?
- The NutriBullet Select 1200 / 2.0 Select 1200 easy-twist extractor blade must be aligned and securely fastened to the base of the pitcher.
- After shutdown, empty the pitcher and remove its blade. Hand-wash the blade and pitcher, paying attention to the fitting surfaces; keep the blade seal in place and dry the blade completely.
- Twist the easy-twist extractor blade back onto the pitcher base, keeping the components aligned. If the blade will not tighten securely or its seal is damaged, replace the affected blade assembly.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Select 1200 / 2.0 Select 1200, then wait until every moving part has stopped.
- Remove the cup and easy-twist extractor blade together or unlock and remove the pitcher. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Select 1200 / 2.0 Select 1200 Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade, pitcher and lid separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Pro+ 1200 / Pro Plus 1200
The NutriBullet Pro+ 1200 / Pro Plus 1200 can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Pro+ 1200 / Pro Plus 1200 cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Pro+ 1200 / Pro Plus 1200 cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Pro+ 1200 / Pro Plus 1200 extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet Pro+ 1200 / Pro Plus 1200 cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Pro+ 1200 / Pro Plus 1200 cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Pro+ 1200 / Pro Plus 1200 cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Pro+ 1200 / Pro Plus 1200 mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Do not run more than three one-minute intervals without two to three minutes of cooling after the third.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Pro+ 1200 / Pro Plus 1200 cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Pro+ 1200 / Pro Plus 1200, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Pro+ 1200 / Pro Plus 1200 Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 2.0 Pro 1000 โ New Zealand
The NutriBullet 2.0 Pro 1000 NB07100-1008DG โ New Zealand can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Check the NutriBullet 2.0 Pro 1000 cupโs fill level, tighten the easy-twist extractor blade and inspect the cup and blade for damage. These instructions apply to NB07100-1008DG in New Zealand.
Is the cup filled above its MAX line?
- Check the NutriBullet 2.0 Pro 1000 NB07100-1008DG cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and easy-twist extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the easy-twist extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 2.0 Pro 1000 NB07100-1008DG cup and easy-twist extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the easy-twist extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 2.0 Pro 1000 NB07100-1008DG easy-twist extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the easy-twist extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 2.0 Pro 1000 NB07100-1008DG cup and inspect the detachable parts for damage before reassembly.
- Inspect the detached easy-twist extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 2.0 Pro 1000 NB07100-1008DG cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the easy-twist extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 2.0 Pro 1000 NB07100-1008DG cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 2.0 Pro 1000 NB07100-1008DG mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 2.0 Pro 1000 NB07100-1008DG cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the easy-twist extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 2.0 Pro 1000 NB07100-1008DG, then wait until every moving part has stopped.
- Remove the cup and easy-twist extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 2.0 Pro 1000 NB07100-1008DG Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 1000 Series
The NutriBullet 1000 Series can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 1000 Series cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 1000 Series cup and Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Extractor Blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 1000 Series Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 1000 Series cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached Extractor Blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 1000 Series cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the Extractor Blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 1000 Series cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 1000 Series mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Before another one-minute cycle, let contents settle for two to three minutes and open the cool cup carefully to release pressure.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 1000 Series cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 1000 Series, then wait until every moving part has stopped.
- Remove the cup and Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 1000 Series Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Turbo 1000
The NutriBullet Turbo 1000 can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Turbo 1000 cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Turbo 1000 cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Turbo 1000 Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Turbo 1000 cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Turbo 1000 cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Turbo 1000 cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Turbo 1000 mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Do not run more than three consecutive 45-second cycles in five minutes; after that limit, unplug and cool for at least 20 minutes.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Turbo 1000 cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Turbo 1000. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Turbo 1000, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Turbo 1000 Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 1000 Mega Pack / 1000 Series Mega Pack
The NutriBullet 1000 Mega Pack / 1000 Series Mega Pack (N10-1107AK) can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
For product code N10-1107AK.
Is the cup filled above its MAX line?
- Check the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup and Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Extractor Blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached Extractor Blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the Extractor Blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Before another one-minute cycle, let contents settle for two to three minutes and open the cool cup carefully to release pressure.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 1000 Mega Pack / 1000 Series Mega Pack, then wait until every moving part has stopped.
- Remove the cup and Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 1000 Mega Pack / 1000 Series Mega Pack Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 1200 Series / 12 Piece
The NutriBullet 1200 Series / 12 Piece can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 1200 Series / 12 Piece cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 1200 Series / 12 Piece cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 1200 Series / 12 Piece extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 1200 Series / 12 Piece cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 1200 Series / 12 Piece cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 1200 Series / 12 Piece cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 1200 Series / 12 Piece mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 1200 Series / 12 Piece cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 1200 Series / 12 Piece, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 1200 Series / 12 Piece Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 1200 Series / 10 Piece
The NutriBullet 1200 Series / 10 Piece can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 1200 Series / 10 Piece cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 1200 Series / 10 Piece cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 1200 Series / 10 Piece extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 1200 Series / 10 Piece cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 1200 Series / 10 Piece cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 1200 Series / 10 Piece cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 1200 Series / 10 Piece mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 1200 Series / 10 Piece cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 1200 Series / 10 Piece, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 1200 Series / 10 Piece Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 2.0 Pro 1200
The NutriBullet 2.0 Pro 1200 can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 2.0 Pro 1200 cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and easy-twist extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the easy-twist extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 2.0 Pro 1200 cup and easy-twist extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the easy-twist extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 2.0 Pro 1200 easy-twist extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the easy-twist extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 2.0 Pro 1200 cup and inspect the detachable parts for damage before reassembly.
- Inspect the detached easy-twist extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 2.0 Pro 1200 cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the easy-twist extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 2.0 Pro 1200 cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 2.0 Pro 1200 mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 2.0 Pro 1200 cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the easy-twist extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 2.0 Pro 1200, then wait until every moving part has stopped.
- Remove the cup and easy-twist extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 2.0 Pro 1200 Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 500 Series / 4 Piece
The NutriBullet 500 Series / 4 Piece can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 500 Series / 4 Piece cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 500 Series / 4 Piece cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 500 Series / 4 Piece extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 500 Series / 4 Piece cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 500 Series / 4 Piece cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 500 Series / 4 Piece cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 500 Series / 4 Piece mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 500 Series / 4 Piece cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 500 Series / 4 Piece, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 500 Series / 4 Piece Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet 1000 Essentials McLaren
For NutriBullet 1000 Essentials McLaren N10-0807GO-MC, an overfilled cup, an insecure cup-to-blade connection, a damaged seal or pressure from hot or carbonated ingredients can lead to leaks.
Is the cup warm or pressurised?
- Stop blending and unplug the motor base; wait until all moving parts have stopped.
- If the sealed cup feels warm, let it cool before carefully opening it away from your body.
- For the next blend, use cool or room-temperature ingredients, never hot liquids or carbonated ingredients; do not run continuously for more than one minute.
Is the cup overfilled, or is the blade or gasket not sealing?
- With the appliance unplugged and any warm cup cooled, keep ingredients at or below the MAX line and screw the extractor blade securely onto the cup.
- Check that the gasket is fully seated in the blade unit before each use. Leave the gasket in place; if its seal is damaged, replace the complete blade assembly. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
How should I clean up after a leak?
- Unplug and wait for moving parts to stop before cleaning. Wipe the base with a cloth dampened with warm soapy water. NEVER submerge the motor base in water.
- Wash the cups and To-Go Lids on the dishwasher top rack without a sanitise cycle; keep the blade gasket in place and dry both sides of the extractor blade completely.
NutriBullet 700 Series
The NutriBullet 700 Series can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 700 Series cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 700 Series cup and Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Extractor Blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 700 Series Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 700 Series cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached Extractor Blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 700 Series cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 15 minutes and until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the Extractor Blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 700 Series cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 700 Series mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Allow at least one minute between cycles; let a warm cup cool completely before opening it.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 700 Series cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Extractor Blade belong to the NutriBullet 700 Series. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 700 Series, then wait until every moving part has stopped.
- Remove the cup and Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 700 Series Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Select 1000 / Select 1000 with pitcher
The NutriBullet Select 1000 / Select 1000 with pitcher can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Select 1000 / Select 1000 with pitcher cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and easy-twist extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the easy-twist extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Select 1000 / Select 1000 with pitcher cup and easy-twist extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the easy-twist extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Select 1000 / Select 1000 with pitcher easy-twist extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- Do not pull out the easy-twist extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet Select 1000 / Select 1000 with pitcher cup and inspect the detachable parts for damage before reassembly.
- Inspect the detached easy-twist extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Select 1000 / Select 1000 with pitcher cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the easy-twist extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Select 1000 / Select 1000 with pitcher cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Select 1000 / Select 1000 with pitcher mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Select 1000 / Select 1000 with pitcher cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the easy-twist extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are liquid and solid ingredients below the correct pitcher MAX marks?
- Check the NutriBullet Select 1000 / Select 1000 with pitcher pitcher markings before running the blender. Keep liquids below the liquid MAX line and solids below the solid MAX line where separate marks are provided.
- Switch off, disconnect power and wait for the blades to stop, then remove the pitcher and reduce an excessive batch.
- Refit the closed lid before blending again. The ingredients must stay within the appropriate MAX mark after everything has been added.
Are the pitcher lid and its opening securely closed?
- A lid or opening left unsecured can let the NutriBullet Select 1000 / Select 1000 with pitcher pitcher splash from the top. Stop the blades before adjusting the lid.
- Remove the lid and wash food deposits from the lid and pitcher contact surfaces with soap and water, then rinse.
- Seat the lid fully and secure the vented lid cap before blending. The lid must stay fully seated; replace a damaged detachable lid before further use.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Select 1000 / Select 1000 with pitcher, then wait until every moving part has stopped.
- Remove the cool NutriBullet Select 1000 / Select 1000 with pitcher cup and easy-twist extractor blade together, turn the cup upright and unscrew the blade.
- Wipe the accessible NutriBullet Select 1000 / Select 1000 with pitcher Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Pro+ Matte Black
The NutriBullet Pro+ Matte Black can leak if its cup is overfilled, its extractor blade is loose or worn, or the blade seal is dislodged or damaged.
Check these parts with the appliance off and the cup cool.
Is the cup overfilled?
- With the NutriBullet Pro+ Matte Black off and disconnected from power, wait until movement has stopped and the cup is cool before handling the cup and blade.
- Check the combined ingredients and liquid against the cupโs MAX line. Reduce the amount if it is above that line; do not restart with an overfilled cup.
Is the extractor blade loose on the cup?
- With the appliance off, power disconnected and the cup cool, remove the cup and blade assembly from the base. NEVER submerge the motor base in water.
- Tighten the extractor blade securely onto the cup before reattaching the complete assembly. If the connection will not secure normally, keep it out of use.
Is the blade worn, or is its seal dislodged or damaged?
- Inspect the NutriBullet Pro+ Matte Black extractor blade and its seal without dismantling them.
- Stop using the blade at the first sign of wear or damage. A dislodged or damaged seal requires a replacement complete blade assembly; tightening the cup is not a repair.
Were hot or carbonated ingredients put in the cup?
- Do not blend warm, hot or carbonated ingredients in the sealed NutriBullet Pro+ Matte Black cup.
- Stop blending and leave a warm sealed cup alone until cool. If it remains stuck or you need help opening it, leave it off.
What if the cup is damaged, cleaning is needed or the leak continues?
- Keep the appliance off. Take your claim, with your receipt, to the place of purchase (the manufacturer warranty is 12 months from the date of purchase).
- Ask for the cleaning, drying and refitting instructions for this exact product code before taking the assembly apart; do not run another blend to investigate the leak.
NutriBullet 600 Essentials Kit
The NutriBullet 600 Essentials Kit can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 600 Essentials Kit cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 600 Essentials Kit cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 600 Essentials Kit extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 600 Essentials Kit cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 600 Essentials Kit cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 600 Essentials Kit cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 600 Essentials Kit mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 600 Essentials Kit cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 600 Essentials Kit, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 600 Essentials Kit Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Ultra 1200 McLaren / Club Pack
The NutriBullet Ultra 1200 McLaren / Club Pack can leak when its cup is overfilled, its blade is not tightly sealed or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Ultra 1200 McLaren / Club Pack cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Ultra 1200 McLaren / Club Pack cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Ultra 1200 McLaren / Club Pack Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Ultra 1200 McLaren / Club Pack cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Ultra 1200 McLaren / Club Pack cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Ultra 1200 McLaren / Club Pack cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Ultra 1200 McLaren / Club Pack mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. After repeated cycles, allow the contents to settle for at least 10โ15 minutes; a warm cup requires the longer cooling procedure above.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Ultra 1200 McLaren / Club Pack cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Ultra 1200 McLaren / Club Pack. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Ultra 1200 McLaren / Club Pack, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Ultra 1200 McLaren / Club Pack Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Ultra 1200 Premium
The NutriBullet Ultra 1200 Premium can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Ultra 1200 Premium cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Ultra 1200 Premium cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Ultra 1200 Premium Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement extractor blade (New Zealand).
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Ultra 1200 Premium cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement. Buy a replacement extractor blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Ultra 1200 Premium cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Ultra 1200 Premium cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Ultra 1200 Premium mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. After repeated cycles, allow the contents to settle for at least 10โ15 minutes; a warm cup requires the longer cooling procedure above.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Ultra 1200 Premium cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Ultra 1200 Premium. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Ultra 1200 Premium, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Ultra 1200 Premium Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
Magic Bullet To Go 200W
The Magic Bullet To Go 200W can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the Magic Bullet To Go 200W cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Cross Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Cross Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the Magic Bullet To Go 200W cup and Cross Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Cross Blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the Magic Bullet To Go 200W Cross Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal. Buy a replacement cross blade (Australia) or cross blade (New Zealand).
- Do not pull out the Cross Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the Magic Bullet To Go 200W cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached Cross Blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement. Buy a replacement cross blade (Australia) or cross blade (New Zealand).
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed Magic Bullet To Go 200W cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the Cross Blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed Magic Bullet To Go 200W cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the Magic Bullet To Go 200W mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the Magic Bullet To Go 200W cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Cross Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the Magic Bullet To Go 200W, then wait until every moving part has stopped.
- Remove the cup and Cross Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible Magic Bullet To Go 200W Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Ultra Plus+ Compact Kitchen System
The NutriBullet Ultra Plus+ Compact Kitchen System can leak when its Cup or Processor Work Bowl is overfilled, its Rapid Extractor Blade is loose, or a vessel or blade gasket is damaged.
Is the blending cup above MAX?
- Check the NutriBullet Ultra Plus+ Compact Kitchen System Cup with all food and liquid included. Overfilling can cause leaks and pressure.
- Stop the motor completely before removing a leaking cup. Once the contents are cool, stand the cup upright, remove the Rapid Extractor Blade and reduce the contents below MAX. Refit the blade tightly.
Is the Rapid Extractor Blade tightly sealed onto the cup?
- With the NutriBullet Ultra Plus+ Compact Kitchen System unplugged, remove the cup assembly and open it upright once cool.
- Wash the cup rim and Rapid Extractor Blade with warm soapy water, using a small brush or sponge for blade residue. Refit the blade squarely and twist until tightly sealed. If the fit remains loose, inspect the cup and blade for damage and replace the affected part. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
Is the blade gasket missing or damaged?
- Inspect the NutriBullet Ultra Plus+ Compact Kitchen System Rapid Extractor Blade before use. Look for a missing or damaged gasket and damage to the blade housing.
- Stop using a blade with a failed gasket and replace the entire blade assembly; do not remove the factory gasket to clean it. Use a genuine blade intended for this system.
Were hot or warm ingredients blended in the cup?
- Never blend hot or warm ingredients in the NutriBullet Ultra Plus+ Compact Kitchen System Cup. If the cup feels warm, leave it in place and do not touch, open, force or continue blending it.
- Allow at least 30 minutes to cool, and wait longer if it is still warm. Only when completely cool, slowly remove it from the base and use a towel to untwist it away from your face and body. If it remains stuck, leave the appliance off and use the help route in this article.
Were blending cycles repeated until the contents heated up?
- Do not blend continuously for more than one minute in the NutriBullet Ultra Plus+ Compact Kitchen System. Do not run more than six consecutive 30-second intervals.
- When running successive cycles, follow the guide pressure-release instructions between cycles and allow contents to settle for 10โ15 minutes after the last extraction cycle. A cup that feels warm requires the longer warm-cup procedure above; do not run another cycle to test a leak.
Were fizzy ingredients blended or food left sealed under the blade?
- Do not add carbonated or effervescent ingredients to the NutriBullet Ultra Plus+ Compact Kitchen System Cup. Check supplement labels for ingredients that release gas.
- After blending, remove the Rapid Extractor Blade and use the To-Go Lid or transfer food to a suitable container. Do not leave food stored under the blade, where spoilage and fermentation can build pressure. Follow the warm-cup instructions if the vessel feels warm.
Is the Cup or Processor Work Bowl damaged?
- Clean and inspect the NutriBullet Ultra Plus+ Compact Kitchen System Cup, Processor Work Bowl and fitted components.
- Stop using and replace a detachable vessel with cracking, cloudiness, warping or other damage. Keep parts away from boiling water, microwaves and dishwasher heat/sanitise cycles; do not force an incompatible part onto the system.
Is the Processor Work Bowl overfilled?
- With the NutriBullet Ultra Plus+ Compact Kitchen System stopped and unplugged, check that ingredients remain below the Work Bowl MAX line.
- Remove the lid first, unlock the bowl assembly, and lift out the blade or disc by its plastic knob. Empty excess food with a spoon or spatula. Refit the attachment securely and align the lid and bowl arrows before processing another batch.
Has forced feeding damaged the Work Bowl or blocked the chute?
- Do not force food down the NutriBullet Ultra Plus+ Compact Kitchen System Processor Feed Chute. If the blade or disc stops, switch off, unplug and wait for all movement to stop.
- Remove the lid, clear the chute and inspect the Work Bowl. Replace a cracked bowl. For the next batch, start the processor before adding ingredients and use only the Food Pusher to move food slowly and steadily.
Was liquid or a moist ingredient added to the dry grinder?
- The NutriBullet Ultra Plus+ Compact Kitchen System Coffee & Dry Spice Grinder is for dry or dehydrated ingredients only. Do not add liquid or moist food.
- Switch off, unplug and remove the attachment after the blade stops. Empty it and separate the Grinding Cup and Grinder Blade for washing; use the blender cup or another suitable appliance for a wet recipe. Keep the grinder off if any component is damaged.
How do I clean and refit the parts after a spill?
- Power off and unplug the NutriBullet Ultra Plus+ Compact Kitchen System and wait until every blade or disc has stopped. For the blending cup, remove the cup and Rapid Extractor Blade assembly from the base; stand the cup upright before unscrewing the blade.
- For the Processor Attachment, turn the Work Bowl Lid counterclockwise and lift it off first. Then turn the Work Bowl and Processor Base counterclockwise off the Motor Base. Lift the blade or disc by its central plastic knob before removing food with a spoon or spatula.
- Separate the processor Work Bowl from its Processor Base by holding the base underneath and turning the bowl counterclockwise. Wash the blade, disc, Work Bowl and lid by hand with a sponge or cloth, soap and water, or on the top dishwasher rack without heat/sanitise. Hand-wash the Processor Base and Blade Adapter.
- For the Coffee & Dry Spice Grinder, disengage it from the Motor Base and separate the Grinding Cup and Grinder Blade. Hand-wash with a sponge or cloth, soap and water, or use the top dishwasher rack without heat/sanitise.
- Rinse the Rapid Extractor Blade with warm soapy water and use a small brush or sponge to lift residue from it. Wipe the Motor Base exterior gently with a damp sponge or cloth and dry with a clean cloth; do not open the housing. NEVER submerge the motor base in water.
- Inspect cleaned parts for cracks, warping, cloudiness or a damaged blade gasket before reassembly. Replace damaged detachable parts; secure the Rapid Extractor Blade tightly on the cup, or reassemble the chosen attachment in the reverse of its removal order. Buy a replacement extractor blade (Australia) or extractor blade (New Zealand).
NutriBullet 600 Mega Pack
The NutriBullet 600 Mega Pack can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet 600 Mega Pack cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and extractor blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the extractor blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet 600 Mega Pack cup and extractor blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the extractor blade, then hand-wash the cup and blade using warm soapy water without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet 600 Mega Pack extractor blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the extractor blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup, its tabs or the blade housing damaged?
- Empty and clean the NutriBullet 600 Mega Pack cup, then inspect its sides, rim and fitting tabs for cracks, crazing, cloudiness or breakage.
- Inspect the detached extractor blade as well. Stop using a cracked cup, damaged tabs or broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet 600 Mega Pack cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool until completely cool; do not try to open it while warm.
- Once cool, point the cup away from your face and body and carefully untwist the extractor blade to release pressure. Do not force a cup that remains stuck; leave the blender off and use the help route.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet 600 Mega Pack cup. Do not use fizzy drinks for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet 600 Mega Pack mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet 600 Mega Pack cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the extractor blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet 600 Mega Pack, then wait until every moving part has stopped.
- Remove the cup and extractor blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet 600 Mega Pack Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; leave the fixed base liners and components in place.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Turbo 1000 Deluxe Set
The NutriBullet Turbo 1000 Deluxe Set can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Turbo 1000 Deluxe Set cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Turbo 1000 Deluxe Set cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Turbo 1000 Deluxe Set Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Turbo 1000 Deluxe Set cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Turbo 1000 Deluxe Set cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Turbo 1000 Deluxe Set cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Turbo 1000 Deluxe Set mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Do not run more than three consecutive 45-second cycles in five minutes; after that limit, unplug and cool for at least 20 minutes.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Turbo 1000 Deluxe Set cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Turbo 1000 Deluxe Set. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Turbo 1000 Deluxe Set, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Turbo 1000 Deluxe Set Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
NutriBullet Turbo Ultimate Pack
The NutriBullet Turbo Ultimate Pack can leak when its cup is overfilled, its blade is not tightly sealed, or its cup or blade gasket is damaged.
Is the cup filled above its MAX line?
- Check the NutriBullet Turbo Ultimate Pack cup with all ingredients and liquid included; filling above MAX leaves too little room and can let the contents escape.
- After the motor stops, disconnect power. Once the cup is cool, remove the cup and Rapid Extractor Blade together, turn the assembly upright, and unscrew the blade.
- Reduce the batch to at or below MAX and screw the Rapid Extractor Blade back on tightly. The mixture must remain below the marked limit; divide a large recipe between batches.
Is the blade squarely aligned and tightly attached?
- Look at the join between the NutriBullet Turbo Ultimate Pack cup and Rapid Extractor Blade; the blade must sit squarely and form a tight seal.
- With power disconnected, remove the cool cup assembly and stand it blade-side up. Unscrew the Rapid Extractor Blade, then hand-wash the cup using warm soapy water; wash the blade on the top rack of the dishwasher (no heat or sanitise cycle) or by hand without touching the cutting edges.
- Rinse and dry the parts. Align the blade with the cup and hand-tighten it securely before returning the complete assembly to the base; stop using any attachment that cannot be secured.
Is the blade gasket loose, missing, removed or damaged?
- Inspect the gasket in the NutriBullet Turbo Ultimate Pack Rapid Extractor Blade before reassembling the cup; it must remain seated and intact.
- A loose, missing, torn or damaged gasket means the blade assembly must not be used. Replace the affected blade assembly rather than operating it with an incomplete seal.
- Do not pull out the Rapid Extractor Blade gasket or dismantle the blade to clean underneath it; wash the accessible surfaces and dry the assembly completely.
Are the cup or blade assembly damaged?
- Empty and clean the NutriBullet Turbo Ultimate Pack cup, then inspect its sides and rim for cracks, crazing, cloudiness or breakage.
- Inspect the detached Rapid Extractor Blade as well. Stop using a cracked cup or a broken blade housing and replace that part with the correct genuine replacement.
- The replacement should attach securely without force. If sound parts still leak after correct fitting and filling, keep the appliance off and use the help route in this article.
Did hot or warm ingredients pressurise the cup?
- Hot ingredients can pressurise the sealed NutriBullet Turbo Ultimate Pack cup and push contents out. Start a new cup blend only with refrigerated or room-temperature ingredients.
- If the cup feels hot or warm, stop blending and leave it alone to cool at least 30 minutes, and longer until completely cool; do not try to open it while warm.
- When the cup is fully cool, remove it slowly from the base. Point it away from your face and body, cover the Rapid Extractor Blade with a towel, and slowly untwist it; do not force stuck parts apart.
Were carbonated or effervescent ingredients used?
- Carbonated ingredients release gas in the sealed NutriBullet Turbo Ultimate Pack cup. Do not use fizzy drinks or effervescent powders for a cup blend.
- Stop further blending if the mixture is pressurised. Follow the warm-cup cooling steps above before opening a warm vessel.
- For the next batch, use a non-carbonated liquid and check the ingredient list before adding a powder or supplement.
Did blending run for too long or repeat without a rest?
- Blade friction can warm the NutriBullet Turbo Ultimate Pack mixture during prolonged or repeated blending, allowing pressure to build.
- Keep each continuous blend to no more than one minute. Do not run more than three consecutive 45-second cycles in five minutes; after that limit, unplug and cool for at least 20 minutes.
- Do not restart repeatedly to investigate a leak. Let the contents cool, then finish the cup, blade and filling checks before using the blender again.
Was blended food left sealed under the blade?
- Blended food left sealed in the NutriBullet Turbo Ultimate Pack cup can ferment and release gas, so the blade assembly must not be used as a storage lid.
- After blending and safe pressure release, remove the Rapid Extractor Blade; use the intended storage lid or transfer the mixture to another suitable container.
- If an old blend has left the cup warm or stuck, stop handling it and use the warm-cup procedure above. Never add another blending cycle to try to release it.
Are the cup and blade the correct parts for this model?
- Check that the cup and Rapid Extractor Blade belong to the NutriBullet Turbo Ultimate Pack. Use only the cup and blade intended for this model.
- Remove the unsuitable attachment after shutdown and check that its product code matches your machine.
- Use only the genuine matching cup and blade combination. Do not force a thread or reuse a part that cannot sit securely.
How do I clean and refit the parts after a spill?
- Switch off and unplug the NutriBullet Turbo Ultimate Pack, then wait until every moving part has stopped.
- Remove the cup and Rapid Extractor Blade together. Empty the cool vessel and separate its detachable parts for washing.
- Wipe the accessible NutriBullet Turbo Ultimate Pack Motor Base surfaces with a sponge or cloth dampened with warm soapy water. NEVER submerge the motor base in water. Do not remove the motor base's housing parts.
- Use a small brush to loosen sticky debris around the actuator area while the base remains unplugged; keep the Motor Base intact.
- Wash the detachable cup and blade separately with soap and water, keeping fingers away from the cutting edges. Rinse the washable parts and dry them before reassembly.
- Check that the accessible base is free of food and moisture before refitting the clean parts. If liquid has entered the housing, follow the liquid-in-base advice in this article instead of restarting.
Still need help? Chat with us and give us your model name and product code.
The full steps for this model are in its user guide: NutriBullet Ultra 1200 user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 900 Series user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 900 Essentials Set NB9-0807DG user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 900 Mega Pack NB9-1107AK user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 600 Series user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Ultra 1000 / Ultra 1000 Premium user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Select 1200 / 2.0 Select 1200 user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Pro+ 1200 / Pro Plus 1200 user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 2.0 Pro 1000 NB07100-1008DG user guide (NZ, PDF)
The full steps for this model are in its user guide: NutriBullet 1000 Series user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Turbo 1000 user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 1000 Mega Pack / 1000 Series Mega Pack user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 1200 Series / 12 Piece user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 1200 Series / 10 Piece user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 500 Series / 4 Piece user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 1000 Essentials McLaren N10-0807GO-MC user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 700 Series user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Select 1000 / Select 1000 with pitcher user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 600 Essentials Kit user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Ultra 1200 McLaren / Club Pack user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Ultra 1200 Premium user guide (PDF)
The full steps for this model are in its user guide: Magic Bullet To Go 200W user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Ultra Plus+ Compact Kitchen System user guide (PDF)
The full steps for this model are in its user guide: NutriBullet 600 Mega Pack user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Turbo 1000 Deluxe Set user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Turbo Ultimate Pack user guide (PDF)