Replace a damaged sieve or auger before using your juicer again; if extraction falls, clean away pulp buildup and inspect the part first.
Use the juicer replacement-parts guide to match a new part. If extreme vibration occurs or you cannot identify a damaged part, stop using the juicer and take your claim, with your receipt, to the place of purchase (the manufacturer warranty is 12 months from the date of purchase).
What should I check before changing juicing parts?
- Switch OFF, unplug and wait for the motor and all moving parts to stop before assembly, disassembly or cleaning. Pull the plug itself, not the cord.
- Choose parts sold or recommended for the exact juicer model below; do not substitute a similar-looking part from another juicer.
- Keep fingers away from cutting teeth, sharp screen edges and the feed chute. Use the supplied pusher for food and the cleaning brush for sharp juicing surfaces.
- Inspect detachable parts for wear or damage before fitting them. Stop using a damaged part and replace it before running the juicer again.
NutriBullet Juicer 800W
Replace the sieve before further use if torn, crinkled, deformed or otherwise damaged; with heavy use, replace it every 12 months or sooner as needed. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
When does the sieve need replacing?
- On the NutriBullet Juicer 800W, stop using the sieve if its filter mesh is torn, crinkled or deformed, or if any part of the rotating sieve is damaged. Replace the complete sieve before juicing again. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
- For heavy use, replace the NutriBullet Juicer 800W sieve every 12 months, or earlier as needed. Do not wait for that interval if the mesh or cutting teeth are damaged. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
- If the NutriBullet Juicer 800W becomes louder or develops unusual noise or vibration, stop and inspect the sieve and cleaning brush for wear. These are consumable parts; continued use of worn parts can lead to failure.
- If the cleaned NutriBullet Juicer 800W sieve looks dull or still extracts less efficiently, replace it with the correct genuine sieve rather than continuing with a worn cutting surface. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
- Use genuine NutriBullet replacement parts; aftermarket parts may cause the juicer to malfunction.
How do I remove and inspect the sieve and basin?
- Remove the NutriBullet Juicer 800W juice pitcher and close the no-drip outlet before lifting the basin: swing the NBJ07100 spout cover down over the opening.
- Pull the locking handle backwards out of the two cover ears and lower it. Lift the pulp basin off the motor base with its cover and sieve still inside, and take the assembly to the sink.
- Lift out the food pusher, then lift the basin cover straight up. Use the flat end of the cleaning brush to remove pulp from the cover; gently lift the sieve vertically out of the basin by its rim without touching the cutting teeth.
- Empty the pulp basin and remove remaining pulp with the flat end of the cleaning brush. Check the emptied basin, cover, pusher, sieve and pitcher for cracks, distortion or wear before reassembly.
Could blocked sieve holes be reducing performance?
- Immediately after using the NutriBullet Juicer 800W, rinse the removable parts under running water. Scrub the sieve with the cleaning brush under running water until pulp is removed from the holes; do not touch the blade teeth.
- If pulp has dried onto the sieve, soak the sieve in hot water for 30 minutes, then brush and rinse it again. Recheck the mesh for damage after the residue is removed.
- Hand-wash the NutriBullet Juicer 800W food pusher in warm soapy water. Wash the other detachable parts in warm soapy water or in the dishwasher without a sterilise cycle; wipe the motor base with a damp cloth.
How do I refit the parts and check operation?
- With the NutriBullet Juicer 800W unplugged, place the pulp basin on the base with its spout aligned to the dimpled side. Align the sieve with the motor drive coupling and press it down by the rim until it clicks and sits securely inside the basin.
- Align the cover ears with the basin ears and raise the locking handle into them until it locks. The handle must be secure before operation; if it will not lock, remove and reseat the basin, sieve and cover instead of forcing it.
- For the original NutriBullet Juicer 800W NBJ07100, swing the no-drip cover upwards to open it. Open the pitcher-lid locking latch, angle the pitcher so the spout enters that opening, then set it level.
- Start the juicer before feeding food, use the food pusher gently and add ingredients gradually. Empty a full pulp basin before continuing; do not force food into the sieve to compensate for poor extraction.
How should I store the parts?
- Store the NutriBullet Juicer 800W juice pitcher upright with its lid secured and nothing on top; keep loose sharp parts in a safe place where they cannot be damaged or cause injury.
NutriBullet Cold Press Slow Juicer
Replace a damaged auger or other detachable juicing part with the matching NBJ07300 part before reassembling or using the juicer.
Which damage means I should replace a part?
- Inspect the NutriBullet Cold Press Slow Juicer auger and juicing screen after removing them. Do not use a damaged auger; stop using a damaged detachable part and replace it with the correct NBJ07300 part before reassembly.
- If juice output has fallen, clean the NutriBullet Cold Press Slow Juicer screen and pulp outlet before deciding the grinding assembly is worn. Blocked screen holes can reduce extraction even when the parts are intact.
How do I take the grinding assembly apart?
- Let the NutriBullet Cold Press Slow Juicer cool completely after switching off and unplugging; confirm that the auger, motor and all moving parts have stopped. Remove both containers and close the juice spout cover.
- Turn the juice bowl cover counter-clockwise to unlock it and lift it away. Lift out the auger, then lift the juice bowl off the base; lift out the screen and rotating bowl brush and slide the brush down off the screen. Remove the food pusher from the chute.
- If intact parts are difficult to separate immediately after juicing, the NutriBullet Cold Press Slow Juicer guide suggests letting remaining food process for about 30 seconds without adding more food, or pouring water through the feed chute to loosen it. Then switch off, unplug, wait for all movement to stop and try disassembly again; do not run an empty dry grinding assembly.
How do I clean and check each removable part?
- Separate and empty the NutriBullet Cold Press Slow Juicer parts, then rinse the cover, pusher, auger, screen, rotating bowl brush, bowl and both containers under running water. Wash them in warm soapy water; avoid metal sponges.
- Always wash the NutriBullet Cold Press Slow Juicer auger by hand with warm soapy water and a soft cloth. The remaining detachable parts can go in the dishwasher; keep the motor base out and wipe its exterior with a damp cloth.
- Brush the sharp juicing screen under running water after every use until its holes are clear. Soak detachable parts with dried-on pulp in hot water for 30 minutes to soften the residue, then clean them again.
- Pull the pulp plug out of the pulp spout; use the narrow end of the cleaning brush to clear the outlet and run water through the bowl and spout. Before refitting, return the pulp plug to its proper position underneath the juice bowl.
How do I refit the grinding assembly and containers?
- Press the NutriBullet Cold Press Slow Juicer juice bowl down onto the motor base until it is securely fastened. Fit the juicing screen into the rotating bowl brush, lower both into the bowl and turn slightly if needed until seated.
- Lower the auger onto the centre axis inside the screen; turn and press its head until it sits securely. Align the unlocked symbol on the cover with the bowl arrow, then turn clockwise until the locked symbol aligns with the bowl triangle.
- Place the NutriBullet Cold Press Slow Juicer juice container under the right-hand juice spout with its cover, and place the pulp container under the pulp spout. Insert the food pusher; the bowl and cover must be properly locked before operation.
- Feed prepared food gently with the NutriBullet Cold Press Slow Juicer food pusher, never fingers or utensils. When the juice container fills, switch off and empty both containers before the next round; avoid overloading the chute.
How should I dry and store the parts?
- Dry all NutriBullet Cold Press Slow Juicer parts thoroughly, reassemble and store in a safe, dry place. The juice container can sit inside the pulp container; carry the appliance by its base, not its juice bowl or cover.
NutriBullet Juicer Pro 1000W
Replace the sieve immediately if its mesh or any rotating part is damaged; heavy use calls for replacement every 12 months or earlier when needed. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
When does the sieve need replacing?
- On the NutriBullet Juicer Pro 1000W, stop using the sieve if its filter mesh is torn, crinkled or deformed, or if any part of the rotating sieve is damaged. Replace the complete sieve before juicing again. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
- For heavy use, replace the NutriBullet Juicer Pro 1000W sieve every 12 months, or earlier as needed. Do not wait for that interval if the mesh or cutting teeth are damaged. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
- If the NutriBullet Juicer Pro 1000W becomes louder or develops unusual noise or vibration, stop and inspect the sieve and cleaning brush for wear. These are consumable parts; continued use of worn parts can lead to failure.
- If the cleaned NutriBullet Juicer Pro 1000W sieve looks dull or still extracts less efficiently, replace it with the correct genuine sieve rather than continuing with a worn cutting surface. Buy a replacement sieve/screen (Australia) or sieve/screen (New Zealand).
How do I remove and inspect the sieve and basin?
- Remove the NutriBullet Juicer Pro 1000W juice pitcher and swing the no-drip spout cover down over the opening before lifting the basin.
- Pull the locking handle backwards out of the two cover ears and lower it. Lift the pulp basin off the motor base with its cover and sieve still inside, and take the assembly to the sink.
- Lift out the food pusher, then lift the basin cover straight up. Use the flat end of the cleaning brush to remove pulp from the cover; gently lift the sieve vertically out of the basin by its rim without touching the cutting teeth.
- Empty the pulp basin and remove remaining pulp with the flat end of the cleaning brush. Check the emptied basin, cover, pusher, sieve and pitcher for cracks, distortion or wear before reassembly.
Could blocked sieve holes be reducing performance?
- Immediately after using the NutriBullet Juicer Pro 1000W, rinse the removable parts under running water. Scrub the sieve with the cleaning brush under running water until pulp is removed from the holes; do not touch the blade teeth.
- If pulp has dried onto the sieve, soak the sieve in hot water for 30 minutes, then brush and rinse it again. Recheck the mesh for damage after the residue is removed.
- Hand-wash the NutriBullet Juicer Pro 1000W food pusher in warm soapy water; wash the sieve and other detachable parts in warm soapy water or in the dishwasher, without a sterilise cycle. The motor base only needs a clean, damp cloth.
How do I refit the parts and check operation?
- With the NutriBullet Juicer Pro 1000W unplugged, place the pulp basin on the base with its spout aligned to the dimpled side. Align the sieve with the motor drive coupling and press it down by the rim until it clicks and sits securely inside the basin.
- Align the cover ears with the basin ears and raise the locking handle into them until it locks. The handle must be secure before operation; if it will not lock, remove and reseat the basin, sieve and cover instead of forcing it.
- For NutriBullet Juicer Pro 1000W, swing the no-drip spout cover upwards to open it. Put the lid on the pitcher, open its latch, angle the pitcher so the spout enters the lid opening, then set the pitcher level.
- For smaller ingredients, hold the NutriBullet Juicer Pro 1000W pusher at the top and bottom and twist the top clockwise to release the inner pusher. Leave the outer pusher in the chute and guide food through it with the inner pusher; for larger pieces, lock both pusher sections together and use the full-width chute.
- Start the juicer before feeding food, use the food pusher gently and add ingredients gradually. Empty a full pulp basin before continuing; do not force food into the sieve to compensate for poor extraction.
How should I store the parts?
- Store the NutriBullet Juicer Pro 1000W juice pitcher upright with its lid secured and nothing on top; keep loose sharp parts in a safe place where they cannot be damaged or cause injury.
- The NutriBullet Juicer Pro 1000W glass storage bottles and their lids, and freezer trays and their lids, are dishwasher-safe. Keep fresh juice refrigerated in the sealed pitcher or bottles and use it within 48 hours; use the trays for longer storage.
- When filling each NutriBullet Juicer Pro 1000W 350 mL glass bottle, leave about 0.6 cm of space at the top. Do not stack anything on the pitcher lid in the refrigerator.
NutriBullet Cold Press Batch Juicer
Replace a cracked, bent or damaged auger before running the juicer again, and replace other removable parts showing wear or damage.
What damage requires a replacement?
- Check the NutriBullet Cold Press Batch Juicer auger before every use. Replace an auger that is cracked, bent or damaged; never run it to test whether it still works.
- Periodically inspect the NutriBullet Cold Press Batch Juicer hopper, juicing bowl and other removable parts for cracks, wear or damage. Stop using any affected part and obtain the correct genuine replacement; do not use a damaged rotating sieve or strainer if fitted.
- If the NutriBullet Cold Press Batch Juicer extracts poorly, clean the auger, hopper and juicing bowl first. Residue buildup can prevent proper operation, so check the cleaned parts before deciding that the auger needs replacement.
How do I remove the auger and bowl?
- Turn the NutriBullet Cold Press Batch Juicer dial OFF and unplug; wait until the auger stops completely. Open the lid, turn the hopper counter-clockwise by its handle until the arrows no longer align, then lift it away.
- Pull the NutriBullet Cold Press Batch Juicer auger straight up out of the juicing bowl. Lift the bowl up and off the base, then empty the hopper and bowl before rinsing.
How do I clean the parts before inspecting or refitting them?
- Rinse NutriBullet Cold Press Batch Juicer detachable parts under running water after use. Scrub the auger with the cleaning brush and remove residue from the hopper and juicing bowl so no buildup remains.
- Clean underneath the NutriBullet Cold Press Batch Juicer bowl, including the silicone cover, spouts and spout cover. Push the silicone cover firmly back into place after cleaning and check that it is fully seated and flush.
- Wash NutriBullet Cold Press Batch Juicer detachable parts in warm soapy water or in the dishwasher without a sterilise cycle. Do not use metal sponges or abrasive pads; wipe the motor base with a damp cloth.
- Keep NutriBullet Cold Press Batch Juicer parts out of the microwave and do not immerse them in boiling water or hold them over boiling water. These heat treatments can damage the parts.
How do I fit the replacement and check the assembly?
- With the NutriBullet Cold Press Batch Juicer off and unplugged, align the bowl spouts with the base notches and press the bowl firmly down. Insert the auger in the centre and press it to the bottom until it locks; an incorrectly seated auger prevents the hopper closing.
- With the NutriBullet Cold Press Batch Juicer lid open, place the hopper over the bowl and turn it clockwise until the orange dot disappears. Close the lid after fitting; the juicer will not start without the auger correctly in place and the lid closed.
- Put the NutriBullet Cold Press Batch Juicer juice cup under the juice spout and its pulp cup under the pulp spout. Open the juice spout cover to let juice flow, and close it when finished.
- Use only the NutriBullet Cold Press Batch Juicer 2-in-1 pusher and scraper tool to guide food or scrape the hopper sides. Do not overload the hopper or force ingredients; if food sticks, the REVERSE dial setting briefly turns the auger backwards to release it.
How do I store the juicing parts?
- Store the NutriBullet Cold Press Batch Juicer components where they cannot be damaged and sharp parts cannot cause injury. Keep the lid clear of anything stacked on top.
Still need help? Chat with us and give us your model name and product code.
The full steps for this model are in its user guide: NutriBullet Juicer 800W user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Cold Press Slow Juicer user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Juicer Pro 1000W user guide (PDF)
The full steps for this model are in its user guide: NutriBullet Cold Press Batch Juicer user guide (PDF)